Guides

Why Pump Three Well Volumes When Sampling a Well?

Why pump three well volumes for a well sample? See the three-volumes equation, the sampling procedure, contamination routes and when well water needs treatment.

Miryori Editorial Team3 min read
Try the Well Volume Calculator

A groundwater sample is only useful if it represents the water currently flowing into the well, not water that has been sitting untouched in the hole. That is why sampling procedures call for pumping a set amount before collecting the sample. The well volume calculator reports that amount directly, using the same three well measurements it needs for the ordinary volume result.

Pumping out at least three times the volume of water in a well — the water column — is a normal procedure when sampling a well. It produces an accurate, representative groundwater sample and avoids pollution that may have happened while the well was stagnant for a long period. The calculator gives this figure as three well volumes, which is the well volume multiplied by three.

What does pumping three well volumes accomplish?

The purpose is sample quality. Pumping out at least three times the volume of water in the well, known as the water column, is the normal procedure when sampling a well. Doing so ensures you acquire an accurate, representative sample of the groundwater and avoid any pollution that may have occurred as a result of the well being stagnant for an extended period of time. The calculator therefore shows the result of the three volumes alongside the well volume, so the pumping target is available as soon as the measurements are entered.

How do you calculate three well volumes?

The source defines three well volumes as three times the well volume, and the well volume itself comes from the diameter and the water-column height:

well volume=π4×well diameter2×(total well depth−static water depth)\text{well volume} = \frac{\pi}{4} \times \text{well diameter}^{2} \times (\text{total well depth} - \text{static water depth})

three well volumes=3×well volume\text{three well volumes} = 3 \times \text{well volume}

Quantity Source relationship Sourced constant
Well volume π/4 × (Well diameter)² × (Total well depth − Static water depth) π ≈ 3.14159
Three well volumes 3 × Well volume factor 3

How can a well become contaminated?

Most well water doesn't need much filtration if the screen and pump are well maintained. Nevertheless, there are several ways a well can become contaminated. Toxic materials can leach into the aquifer and pollute the groundwater near the well, and contaminated water can get into wells that were installed poorly or not properly maintained. These are the risks the three-volume pumping procedure is designed to work around when you take a sample: the water that has been stagnant in the well is removed before the representative groundwater is collected.

Worked example: three well volumes from the well equation

Name the three measured inputs dd (well diameter), H2H_2 (total well depth) and H1H_1 (static water depth). The water column has height H2−H1H_2 - H_1, so with the source constant π≈3.14159\pi \approx 3.14159:

well volume=3.141594×d2×(H2−H1)\text{well volume} = \frac{3.14159}{4} \times d^{2} \times (H_2 - H_1)

Substituting that result into the three-volumes equation gives the pumping target:

three well volumes=3×3.141594×d2×(H2−H1)=3π4×d2×(H2−H1)\text{three well volumes} = 3 \times \frac{3.14159}{4} \times d^{2} \times (H_2 - H_1) = \frac{3\pi}{4} \times d^{2} \times (H_2 - H_1)

The only new number in the second expression is the factor 3, which the source applies to the well volume. Measuring the three lengths in consistent units is enough to turn this into the volume you should pump before sampling.

Frequently Asked Questions

Does well water usually need filtration?

Most well water doesn't need much filtration if the screen and pump are well maintained, according to the source. Contamination is the reason to test and treat, not a routine feature of every well.

What is the water column?

It is the volume of water in the well — the standing water between the static water level and the bottom. The sampling procedure calls for pumping out at least three times that volume.

Where does well water come from?

Well water comes from groundwater beneath the Earth's surface, including porous water-bearing rocks and subterranean springs. The way it is raised also matters: there are self-rising artesian wells and wells that employ pumping action to bring water to the surface.

Can I check the hardness of my well water?

The source points to a water hardness calculator for working out the hardness of the water you consume.

References

  • Omni Well Volume Calculator: three-well-volumes equation and the sampling procedure described in the source.
  • Well water treatment and groundwater contamination guidance quoted in the source.
  • Cylinder-volume geometry behind the π/4 × diameter² × height expression.
Calculator

Well Volume Calculator

Calculate Well Volume with practical everyday formulas, interactive references and step-by-step results. Free, fast and private.

Try the Well Volume Calculator