Working out your household load in watts is only the first step toward choosing a generator. A generator's nameplate is usually given in kVA (apparent power), not plain watts, so you must convert for efficiency and leave headroom for continuous running. This article covers the sizing formula, the standard power factor and operating-capacity guidelines, and two worked examples from the source data.

To size a generator, divide your generator wattage by the power factor to get apparent power in kVA, then divide by the operating capacity to allow for continuous running. With the standard power factor of 0.8 and a 70% operating capacity, a 3,560 W house needs about 6.357 kVA. A generator should not run at full capacity for long, so sizing always builds in headroom.

How do I convert watts to generator size in kVA?

A generator's rated power is its apparent power, because some power is lost in the system. In an ideal 100%-efficient generator, apparent power and generator wattage would be equal; in the real world you must account for the loss:

Apparent power (kVA)=Gen wattagePower factor\text{Apparent power (kVA)} = \frac{\text{Gen wattage}}{\text{Power factor}}

The power factor is the electrical efficiency, valued between 0 and 1. An international standard generator has a power factor of 0.8. To find the generator size from there, divide the apparent power by the operating capacity (recommended 70–80% of full capacity):

Required generator size=Apparent powerOperating capacity\text{Required generator size} = \frac{\text{Apparent power}}{\text{Operating capacity}}

What power factor and capacity should I use?

The source data uses a power factor of 0.8 (80% efficiency) and recommends operating generators at 70–80% of full capacity, especially when a generator is a main power supply. The generator wattage calculator sets both defaults to 0.8 and 70%, and lets you customize them with the "Specify custom power factor and generator operating capacity" option. The calculator's own sizing logic uses the larger of total rated or total surge watts as the starting wattage.

Sizing input Source value
Power factor (efficiency) 0.8 (80%)
Recommended operating capacity 70–80%
Calculator operating-capacity default 70%
kW to kVA conversion 1 kW = 1 kVA

Beyond the numbers, the source also notes practical factors: the space available on site, and the feasibility of transporting and installing the generator.

Worked example: a 3,560 W house

To power a house needing 3,560 W:

  1. Assume 80% efficiency, giving a power factor of 0.8.
  2. Divide wattage by power factor: 3560/0.8=4450 W=4.45 kW3560 / 0.8 = 4450\ \text{W} = 4.45\ \text{kW} of apparent power.
  3. Convert kilowatts to kilo-volt-amperes (1 kW = 1 kVA): 4.45 kW=4.45 kVA4.45\ \text{kW} = 4.45\ \text{kVA}.
  4. Assume the generator runs at 70% of maximum capacity.
  5. Divide apparent power by 0.7: 4.45/0.7≈6.357 kVA4.45 / 0.7 \approx 6.357\ \text{kVA}.

So the house needs a generator of about 6.357 kVA.

Worked example: how many ACs on a 10 kVA generator?

A room air conditioner of 10,000 BTU needs 1,200 W rated and 2,200 W surge. To find how many will run on a 10 kVA generator at maximum capacity and 80% efficiency:

  1. Convert 10 kVA to kW (1 kVA = 1 kW): 10 kVA = 10 kW.
  2. Apply 80% efficiency: 10 kW×0.8=8 kW10\ \text{kW} \times 0.8 = 8\ \text{kW} of generator watts available.
  3. Divide by one AC's 2,200 W surge draw: 8/2.2=3.636…8 / 2.2 = 3.636\ldots

That rounds down to three air conditioners.

Frequently Asked Questions

Is it better to oversize a generator?

Oversizing can make sense if you plan to add equipment later, but too much capacity brings more problems than benefits. Larger generators cost more, burn more fuel and can build up carbon in the engine. Sizing the generator correctly is essential.

Why not run a generator at 100% capacity?

Generators should not run at total capacity for long, particularly as a main power supply. The source recommends operating at 70–80% of full capacity, which is why sizing divides apparent power by an operating capacity below 100%.

Does a bigger kVA rating always mean more usable watts?

Not directly — usable watts depend on the power factor. At 80% efficiency, a 10 kVA generator supplies 8 kW of generator watts. Always multiply the kVA rating by the power factor before comparing it with your appliance wattage.

References

  • Omni Generator Wattage Calculator source article: "Generator sizing calculation" (apparent power, power factor 0.8, 70–80% operating capacity).
  • Omni source FAQs: the 3,560 W house → 6.357 kVA calculation and the three-ACs-on-10-kVA example.
Calculator

Generator Wattage Calculator

Generator Wattage: generator wattage calculator to estimate the load requirements of your generator. Free, fast and private.

Try the Generator Wattage Calculator