Generator sizing always comes down to two numbers on an appliance label: rated watts and surge watts. Confusing the two is the most common way to end up with a generator that runs an appliance but cannot start it. This article defines both terms, explains which appliances need extra startup power, and works through a two-motor example.
Rated watts (running watts) are the maximum power an appliance consumes while it is operating. Surge watts (starting watts) are the higher, brief power an appliance needs when it starts. A generator must supply enough rated watts to run every connected appliance and enough surge watts to start motor-driven equipment; for safety, the required generator wattage is taken as the total surge watts.
How do rated and surge watts combine into generator wattage?
A generator must match the rated watts of every appliance it runs and the surge watts needed to start motor-driven equipment. Adding each figure across all connected appliances gives the two totals:
For safety, the calculator takes the required generator wattage as the total surge watts, whether appliances start together or one at a time. The sections below define each term and show the gap on real appliances.
What does rated watts mean?
An electrical appliance uses electric power to produce some output or effect: a refrigerator uses power to cool its contents, an air conditioner to cool a room, and a bulb to generate light. Every appliance carries a power rating indicating the maximum power it will consume during operation.
An appliance's rated watts, also called running watts, is the power it consumes while operating (or "running"). Although the true power consumption varies through the operation cycle, the rated watts reflect the maximum power consumed during operation. That is the continuous figure a generator must be able to supply for as long as the appliance stays on.
Why do some appliances need surge watts?
Some appliances require higher power than their rated watts when starting. This higher power needed at an appliance's start is known as surge watts or starting watts. It is a short-lived spike, not a continuous draw, but it happens at exactly the moment you switch the appliance on.
Typically, machines that use a motor — such as an air conditioner or a refrigerator — require higher power during start-up. Appliances without motors, like a light bulb, LED TV or wifi router, draw the same power running and starting. The table below shows the gap on real appliances from the source load data:
| Appliance | Rated watts | Surge watts |
|---|---|---|
| Refrigerator | 700 W | 1,500 W |
| Electric range (8 inch element) | 2,100 W | 2,100 W |
| Ceiling fan | 80 W | 120 W |
| Light bulb (15 W×4) | 60 W | 60 W |
| LED TV (50 inch) | 100 W | 100 W |
| Wifi router | 10 W | 10 W |
The refrigerator's surge is more than double its running draw, and the ceiling fan also needs extra starting power. The range, bulb, TV and router have matched rated and surge figures because they have no significant motor start-up.
Worked example: two motors on one generator
Suppose a generator powers two motors. Motor A has 700 W running watts and 2,500 W surge watts; Motor B has 600 W rated watts and 2,000 W starting watts.
If you start both simultaneously, the generator must cover both surge figures at once:
If you start Motor A first and only start Motor B once Motor A is running, the generator covers Motor A's running watts plus Motor B's starting watts:
Staggering the start-ups cuts the peak demand from 4,500 W to 2,700 W. Even so, it is safer to assume generator wattage equals the total surge watts, whether you start everything at once or not — the unused capacity becomes a cushion for future appliances. The generator wattage calculator follows that assumption.
Frequently Asked Questions
Are surge watts the same as starting watts?
Yes. Surge watts and starting watts are two names for the higher, brief power an appliance needs at the moment it starts. Rated watts (running watts) are the power it consumes during normal operation.
Which appliances have high surge watts?
Appliances with motors. The source data shows a refrigerator jumping from 700 W rated to 1,500 W surge and a ceiling fan from 80 W to 120 W, while non-motor devices such as the bulb, TV and router have identical rated and surge figures.
Can I ignore surge watts if I start appliances one at a time?
You can reduce the peak you must cover: start one motor, then switch on the next, so the generator only handles running watts for the first plus surge watts for the second. But assuming the full total surge wattage is safer and leaves room for future appliances.
References
- Omni Generator Wattage Calculator source article: "Rated watts and surge watts of an appliance" and "Is generator wattage equal to total rated watts or total surge watts?"
- Omni source appliance table (six-appliance backup load with rated and surge watts) and the two-motor worked example.